Solar radiation bombards the house’s roof structure
throughout the day. The roof functions as a “solar collector.”
Solar radiation reaches the attic
through a process called “conduction.”
The attic functions as a storage and heat transfer area. The
PCS1 is physically located inside the attic and then transfers this solar radiation from the attic air
into the swimming pool’s water through a process called “forced air convection.”
Is achieved with the optional LX220 control. When the
attic is eight degrees hotter than the pool and the pool needs heat, the LX220 automatically routes
water up to the PCS1 and turns it on. It can even synchronize the pool’s pump by turning it on at
the same time.
automatically. The pool owner simply sets the desired thermostat setting on the LX220.
Flowreversal™ can substantially reduce the pool’s heat demand by allowing the heat to rise from
the main drain. Flowreversal™ is a trademark of Mark Urban, Tustin, California. A pool blanket
can be used when the pool is not in use thereby minimizing heat losses caused by evaporation
(60%). Specifications are subject to change without notice.
• Up to 70,000 gallons with FlowReversal™ valves
• Nominal BTU Rating: 60,000 Btus/hour @ D 32ºF
I.E. Pool water input 72ºF & Attic’s Peak @ 104ºF
• BTU Transfer Range: 20-150,000 Btus per hour
• Attic space required: 3 ft min height to peak; and,
square ft of attic equal to or greater than pool sq ft
• Attic access: Fits through standard 24" o.c. trusses
• Minimum access opening recommended: 21"x 31"
• Can be disassembled for smaller access openings
• PCS1 Size: 33"W x 30"H x 18"D
• PCS1 Weight: 135 pounds
• Shipping Crate Size: 42"W x 38"H x 22"D
• Shipping/Crated Weight: 246-253 pounds
• Power: 220 vac 1.8 amps @ Full Load
• Operating Cost: $5-11 per month @ 9¢ per KW/hour
• U.L. Listed: Coil, Motor & other components
• Plumbing: 1 1/2" or 2" PVC typical
• Pressure Drop: 4-6 PSI typical
• Air Flow Rate: 2500 SCFM
• Water Flow Rate: Range 15-80 GPM
• Optimal Water Flow Rate: 45-55 GPM
• Modes: Manual Off & On
• Optional Automatic Operation: LX220 control